Homepage | Our Group | Contact us
.: Main Link :. .: Welcome :.
 
Calculation to determine use of " StrongBack Products "  
for repair or rehabilitation of pipelines :
Enter information in yellow boxes         -                              Results in red
Enter the REMAINING wall thickness, inches 0.089
Enter the pipe Specified Minimum Yield Strength (SMYS), psi 46,000
Enter the pipe OD, inches 48
Remaining capacity, psi   ( line pressure for correct repair) 123
Calculation for " StrongBack " layers:
Enter system design pressure,PSI(or max work pressure x 1.5) 2427
Barlows formula and StrongBack's ultimate tensile strength   2304
 will indicate the number of layers required for temporary repair /   72.57
rehabilitation:( 8 layer min.up to 10"od/10 layer min.over 10"od )  73
Number of  StrongBack  rolls required.
Enter roll width,                            2 - 3 - 4 - 6 or 10 inches  10
Enter length of repair in inches     ( feet x 12 for inches ) 10
Enter length of roll in inches         ( feet x 12 for inches ) 1080
Enter exactly the following formula:   =sum(p1:pX) ,substitute the
the value of "G14" ( number of layers ) for X  and hit "enter" 0
StrongBack rolls required: (round up to next whole roll or to 14.76
minimise possible waste analyze the decimal portion of this number 
to establish the use of shorter roll equivalent to the decimal fraction )
GS-561G required: ( portion of or number of 2 gallon kits ) 0.21 (of two gallons)
equivalent to pint kits of GS561P 1.7 46.5
88
Installation TIME per meter of pipe is 166.0 minutes, 166
that is equivalent to  50.6 minutes per foot.
( These times are approximate and assume a crew of three qualified technicians for pipes 16" and
larger, and a crew of two for pipes smaller than 16".)
NOTE: These calculations are provided by The StrongBack Corporation 
to estimate the amount of product needed for a particular repair and are
subject to verification by your Engineering Department. The StrongBack
Corporation assumes no responsibility what so ever for the misuse or 
modification to this electronic page.

 

 
.: Copyright © 2007 Bintangdelapan Group, Jakarta, Indonesia :.
Best Viewed with Internet Explorer 6.0 or above in 800 x 600 resolution
Home | Mail us